Contrast sensors | ||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||
Features | |||
![]() |
Dimensions (L x W x H): | 80 mm x 30.4 mm x 53 mm |
![]() |
![]() |
Sensing distance 1): | 10 mm |
![]() |
![]() |
Sensing distance tolerance: | ± 3 mm |
![]() |
![]() |
Light source 2) 3): | LED red, green, blue |
![]() |
![]() |
Light emission: | Long and short side of housing, exchangeable |
![]() |
![]() |
Light spot size: | 1.2 mm x 4.2 mm |
![]() |
![]() |
Light spot direction 4): | Vertical |
![]() |
![]() |
Adjustment: | Static 2-point teach-in |
![]() |
![]() |
1) From front edge of lens 2) Average service life of 100,000 h at TA = +25 °C 3) Wave length: 470 nm, 525 nm, 640 nm 4) In relation to long side of housing |
![]() |
Mechanics/electronics | |||
![]() |
Supply voltage Vs 1): | DC 10 V ... 30 V |
![]() |
![]() |
Ripple 2): | ≤ 5 Vpp |
![]() |
![]() |
Power consumption 3): | < 80 mA |
![]() |
![]() |
Switching frequency 4): | 10 kHz |
![]() |
![]() |
Response time 5): | 50 μs |
![]() |
![]() |
Output type: | NPN: HIGH = approx. VS / LOW ≤ 2 V |
![]() |
![]() |
Switching mode: | NPN |
![]() |
![]() |
bbbbb, teach-in (ET): | NPN:, Run: U = 10 V ... < UV, Teach: U < 2 V |
![]() |
![]() |
Retention time (ET): | 25 ms, non-volatile memory |
![]() |
![]() |
Connection type: | Connector M12, 5-pin |
![]() |
![]() |
Protection class 6): | II |
![]() |
![]() |
Circuit protection: | Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected |
![]() |
![]() |
Enclosure rating: | IP 67 |
![]() |
![]() |
Weight: | Ca. 400 g |
![]() |
![]() |
Housing material: | Zinc diecast |
![]() |
![]() |
Output current Imax.: | 100 mA |
![]() |
![]() |
1) Limit values: operation in short-circuit protected network max. 8 A 2) May not exceed or fall short of VS tolerances 3) Without load 4) With light/dark ratio 1:1 5) Signal transit time with resistive load 6) Reference voltage DC 50 V |
![]() |
Ambient data | |||
![]() |
Ambient temperature: | Operation: -10 ... 55 °C, Storage: -25 ... 75 °C |
![]() |
![]() |
Shock load: | According to IEC 60068 |