227 IEC 01(BV)型电缆的综合数据
导体标称截面
mm2
|
导体种类
|
绝缘厚度规定值mm
|
平均外径上限
mm
|
70℃时最小绝缘电阻
MΩ·km
|
1.5
1.5
2.5
2.5
4
4
6
6
10
10
16
25
35
50
70
95
120
150
185
240
300
400
|
1
2
1
2
1
2
1
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
|
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
|
3.3
3.4
3.9
4.2
4.4
4.8
4.9
5.4
6.4
6.8
8.0
9.8
11.0
13.0
15.0
17.0
19.0
21.0
23.5
26.5
29.5
33.5
|
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
0.0050
0.0050
0.0040
0.0045
0.0035
0.0035
0.0032
0.0032
0.0032
0.0032
0.0030
0.0028
|
注:(1)按 GB/T3956-97规定:正常使用时,导体温度最高为70℃。
(2)绝缘料应采用PVC/C型聚氯乙烯混合物。
(3)平均外径应不大于表中规定的上限值。
一般用途单芯软导体无护套电缆,如表3。
表3 227 IEC 02(RV)型电缆的综合数据
导体标称截面
mm2
|
绝缘厚度规定值
mm
|
平均外径上限
mm
|
70℃时最小绝缘电阻
MΩ·KM
|
1.5
2.5
4
6
10
16
25
|
0.7
0.8
0.8
0.8
1.0
1.0
1.2
|
3.5
4.2
4.8
6.3
7.6
8.8
11.0
|
0.010
, <, SPAN lang=EN-US style="FONT-SIZE: 9pt; FONT-FAMILY: 宋体; LETTER-SPACING: 0.6pt; mso-font-kerning: 0pt; mso-bidi-font-family: 宋体">0.009
0.007
0.006
0.0056
0.0046
0.0044
|
续表3 227 IEC 02(RV)型电缆的综合数据
导体标称截面
mm2
|
绝缘厚度规定值
mm
|
平均外径上限
mm
|
70℃时最小绝缘电阻
MΩ·KM
|
35
50
70
95
120
150
185
240
|
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
|
12.5
14.5
17.0
19.0
21.0
23.5
26.0
29.5
|
0.0038
0.0037
0.0032
0.0032
0.0029
0.0029
0.0029
0.0028
|
注:(1)按 GB/T3956-97规定:正常使用时,导体温度最高为70℃。
(2)绝缘料应采用PVC/C型聚氯乙烯混合物。
(3)平均外径应不大于表中规定的上限值。
内部布线用导体温度为70℃的单芯实心导体无护套电缆,如表4。
表4 227 IEC 05(BV)型电缆的综合数据
导体标称截面
mm2
|
绝缘厚度规定值
mm
|
平均外径上限
mm
|
70℃时最小绝缘电阻MΩ·km
|
0.5
0.75
1
|
0.6
0.6
0.6
|
2.4
2.6
2.8
|
0.015
0.012
0.011
|
注:(1)额定电压300/500V。
(2)按GB/T3956-97规定:正常使用时,导体温度最高为70℃。
(3)绝缘料应采用PVC/C型聚氯乙烯混合物。
(4)平均外径应不大于表中规定的上限值。
内部布线用导体温度为70℃的单芯软导体无护套电缆,如表5。
表5 227 IEC 06(RV)型电缆的综合数据
导体标称截面
mm2
|
绝缘厚度规定值
mm
|
平均外径上限
mm
|
70℃时最小绝缘电阻MΩ·km
|
0.5
0.75
1
|
0.6
0.6
0.6
|
2.6
2.8
3.0
|
0.013
0.011
0.009
|
注:(1)额定电压300/500V。
(2)按GB/T3956-97规定:正常使用时,导体温度最高为70℃。
(3)绝缘料应采用PVC/C型聚氯乙烯混合物。
(4)平均外径应不大于表中规定的上限值。
内部布线用导体温度为90℃的单芯实心导体无护套电缆,如表6。
表6 227 IEC 07(BV—90)型电缆的综合数据
导体标称截面
mm2
|
绝缘厚度规定值
mm
|
平均外径上限
mm
|
70℃时最小绝缘电阻MΩ·km
|
0.5
0.75
1.0
1.5
2.5
|
0.6
0.6
0.6
0.7
0.8
|
2.4
2.6
2.8
3.3
3.9
|
0.015
0.013
0.013
0.011
0.009
|
注:(1)额定电压300/500V。
(2)按GB/T3956-97规定:正常使用时,导体温度最高为90℃。
(3)绝缘料应采用PVC/E型聚氯乙烯混合物。
内部布线用导体温度为90℃的单芯软导体无护套电缆,如表7。
表7 227 IEC 08(RV—90)型电缆的综合数据
导体标称截面
mm2
|
绝缘厚度规定值
mm
|
平均外径上限
mm
|
70℃时最小绝缘电阻MΩ·km
|
0.5
0.75
1.0
1.5
2.5
|
0.6
0.6
0.6
0.7
0.8
|
2.6
2.8
3.0
3.5
4.2
|
0.013
0.012
0.010
0.009
0.009
|
注:(1)额定电压300/500V。
(2)按GB/T3956-97规定:正常使用时,导体温度最高为90℃。
(3)绝缘料应采用PVC/E型聚氯乙烯混合物。
固定布电线用轻型聚氯乙烯绝缘和护套电缆,如表8。
表8 227 IEC 10(BVV)型电缆的综合数据
导体芯数和标称截面mm2
|
导体种类
|
绝缘厚度规定值mm
|
内护层厚度近似值mm
|
护套厚度规定值mm
|
平均外径
|
70℃时最小绝缘电阻
MΩ·km
|
下限
mm
|
上限
mm
|
2*1.5
2*2.5
2*4
2×6
2×10
2×16
2×25
2×35
|
1
2
1
2
1
2
1
2
1
2
2
2
2
|
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
|
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.6
0.6
0.6
0.8
1.0
|
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.6
|
7.6
7.8
8.6
9.0
9.6
10.0
10.5
11.0
13.0
13.5
15.5
18.5
21.0
|
10.0
10.5
11.5
12.0
12.5
13.0
13.5
<, FONT style="FONT-SIZE: 15px; FONT-FAMILY: eWebEditor_Temp_Fon, tName">14.0<, /O:P>
16.5
17.5
20.0
24.0
|
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
0.0052
0.0050
|
续表8 227 IEC 10(BVV)型电缆的综合数据
导体芯数和标称截面mm2
|
导体种类
|
绝缘厚度规定值mm
|
内护层厚度近似值mm
|
护套厚度规定值mm
|
平均外径
|
70℃时最小绝缘电阻
MΩ·km
|
下限
mm
|
上限
mm
|
3×1.5
3×2.5
3×4
3×6
3×10
3×16
3×25
3×35
4×1.5
4×2.5
4×4
4×6
4×10
4×16
4×25
4×35
5×1.5
5×2.5
5×4
5×6
5×10
|
1
2
1
2
1
2
1
2
1
2
2
2
2
1
2
1
2
1
2
1
2
1
2
2
2
2
1
2
1
2
1
2
1
2
1
2
|
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
|
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.6
0.6
0.8
0.8
1.0
0.4
0.4
0.4
0.4
0.4
0.4
0.6
0.6
0.6
0.6
0.8
1.0
1.0
0.4
0.4
0.4
0.4
0.6
0.6
0.6
0.6
0.6
0.6
|
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
|
8.0
8.2
9.2
9.4
10.0
10.5
11.5
12.0
14.0
14.5
16.5
20.5
22.0
8.6
9.0
10.0
10.0
11.5
12.0
12.5
13.0
15.5
16.0
18.0
22.5
24.5
9.4
9.8
11.0
11.0
12.5
13.0
13.5
14.5
17.0
17.5
|
10.5
11.0
12.0
12.5
13.0
13.5
14.5
15.5
17.5
19.0
21.5
26.0
29.0
11.5
12.0
13.0
13.5
14.5
15.0
16.0
17.0
19.0
20.5
23.5
28.5
32.0
12.0
12.5
14.0
14.5
16.0
17.0
17.5
18.5
21.0
22.0
|
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
0.0052
0.0050
0.0044
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
0.0052
0.0050
0.0044
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
|
续表8 227 IEC 10(BVV)型电缆的综合数据
导体芯数和标称截面mm2
|
导体种类
|
绝缘厚度规定值mm
|
内护层厚度近似值mm
|
护套厚度规定值mm
|
平均外径
|
70℃时最小绝缘电阻
MΩ·km
|
下限
mm
|
上限
mm
|
5×16
5×25
5×35
|
2
2
2
|
1.0
1.2
1.2
|
0.8
1.0
1.2
|
1.6
1.6
1.6
|
20.5
24.5
27.5
|
26.0
31.5
35.0
|
0.005 2
0.005 0
0.004 4
|
注:(1)导体种类按GB/T3956-97规定;正常使用时,导体最高温度为70℃。
(2)绝缘应采用PVC/C型聚氯乙烯混合物挤包;内护层由非硫化型橡皮或塑料混合物组成;护套应采用PVC/ST4型聚氯乙烯混合物挤包。
(3)额定电压为300/500V。
聚氯乙烯绝缘扁形无护套电缆(软线),如表9。
表9 227 IEC 42(RVB)型软线的综合数据
导体标称截面
mm2
|
绝缘厚度规定值
mm2
|
平均外形尺寸
|
70℃时最小绝缘电阻
ΜΩ·Km
|
下限
mm
|
下限
mm
|
0.5
0.75
|
0.8
0.8
|
2.5×5.0
2.7×5.4
|
3.0×6.0
3.2×6.4
|
0.016
0.014
|
注:(1)导体种类按GB/T3956-97规定;正常使用时,导体最高温度为70℃。
(2)绝缘应采用PVC/D型聚氯乙烯混合物挤包;在导体之间的绝缘两边应有一凹槽,以便于分离绝缘线芯。
(3)额定电压为300/300V。
聚氯乙烯(双层)户内装饰照明回路用软线,如表10。
表10 227 IEC 43(SVR)型软线的综合数据
,
导 体
标称截面
mm2
|
绝缘各层厚度最小值
mm
|
绝缘总厚度
最小值
mm
|
绝缘厚度
平均值
mm
|
平均外径
上限
mm
|
70℃时最小绝缘电阻 ΜΩ·km
|
0.5
0.75
|
0.2
0.2
|
0.6
0.6
|
0.7
0.7
|
2.7
2.9
|
0.014
0.012
|
注:(1)导体种类按GB/T3956-97规定;正常使用时,导体最高温度为70℃。
(2)绝缘应采用PVC/D型聚氯乙烯混合物,绝缘由两层组成,并用双层同时挤包在导体上,绝缘的内、外层塑料颜色应有明显反差,且全粘在内层绝缘上,外层绝缘颜色优选绿色。
(3)额定电压为300/300V。
轻型聚氯乙烯绝缘护套软线,如表11。
表11 227 IEC 52(RVV)型软线的综合数据
导体标称截面
mm2
|
绝缘厚度
规定值
mm
|
护套厚度
规定值
mm
|
平均外形尺寸
|
70℃时最小绝缘电阻
ΜΩ·Km
|
下限
mm
|
上限
mm
|
2×0.5
2×0.75
3×0.5
3×0.75
|
0.5
0.5
0.5
0.5
|
0.6
0.6
0.6
0.6
|
4.8
或
3.0×4.8
5.2
或
3.2×5.2
5.0
5.4
|
6.0
或
3.6×6.0
6.4
或
3.9×6.4
6.2
6.8
|
2×0.5
2×0.75
3×0.5
3×0.75
|
注:(1)导体种类按GB/T3956-97规定;正常使用时,导体最高温度为70℃。
(2)绝缘应采用PVC/D型聚氯乙烯混合物。圆形软线,绝缘线芯应绞合在一起;扁形软线,则绝缘线芯应平行放置。
(3)护套采用PVC/ST5型聚氯乙烯混合物。
(4)额定电压为300/300V。
普通聚氯乙烯绝缘和护套软电缆,如表12。表12 227 IEC 53(RVV)型软线的综合数据
导体标称截面
mm2
|
绝缘厚度
规定值
mm
|
护套厚度
规定值
mm
|
平均外形尺寸
|
70℃时最小绝缘电阻
ΜΩ·Km
|
下限
mm
|
上限
mm
|
2×0.75
2×1.0
2×1.5
2×2.5
3×0.75
3×1.0
3×1.5
3×2.5
4×0.75
4×1.0
4×1.5
4×2.5
|
0.6
0.6
0.7
0.8
0.6
0.6
0.7
0.8
0.6
0.6
0.7
0.8
|
0.8
0.8
0.8
1.0
0.8
0.8
0.9
1.1
0.8
0.9
0.9
1.1
|
6.0
或
3.8×6.0
6.4
7.4
8.9
6.4
6.8
8.0
9.6
6.8
7.6
8.0
10.5
|
7.6
或
5.2×7.6
8.0
9.0
11.0
8.0
8.4
9.8
12.0
8.6
9.4
11.0
13.0
|
2×0.75
2×1
2×1.5
2×2.5
3×0.75
3×1
3×1.5
3×2.5
4×0.75
4×1
4×1.5
4×2.5
|
续表12 227 IEC 53(RVV)型软线的综合数据
导体标称截面
mm2
|
绝缘厚度
规定值
mm
|
护套厚度
规定值
mm
|
平均外形尺寸
|
70℃时最小绝缘电阻
ΜΩ·Km
|
下限
mm
|
上限
mm
|
5×0.75
5×1.0
5×1.5
5×2.5
|
0.6
0.6
0.7
0.8
|
0.9
0.9
1.1
1.2
|
7.4
8.3
10.0
11.5
|
9.6
10.0
12.0
14.0
|
0.011
0.010
0.010
0.009
|
注:(1)导体种类按GB/T3956-97规定;正常使用时,导体最高温度为70℃。
(2)绝缘应采用PVC/D型聚氯乙烯混合物。圆形软线,绝缘线芯应绞合在一起;扁形软线,则绝缘线芯应平行放置。
(3)护套采用PVC/ST5型聚氯乙烯混合物。
(4)额定电压为300/300V。
|