VOLTAGE: DC-36V ~ -72V INPUT CURRENT: 12.0A(RMS). FOR -48 VDC INRUSH CURRENT: 20A MAX
Output Voltage
Output Current Min.
Output Current Max.
Output Current Peak
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
3.0
32.00
± 5%
± 1%
50mV
-5V
0.1
0.5
± 6%
± 1%
120mV
+12V
2.5
25
+7 / -5 %
± 1%
120mV
-12V
0.1
1.2
± 10%
± 1%
150mV
+3.3V
1.0
25
± 5%
± 1%
50mV
+5VSB
0.1
2
± 5%
± 1%
50mV
* TEMPERATURE RANGE : OPERATING 100C --- 400C * HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95% * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS * HOLD UP TIME: 1.6 ms MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE * DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND * EFFICIENCY: 65% TYPICAL, AT FULL LOAD * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms * OVER LOAD PROTECTION: 130 ± 20%. * OVER VOLTAGE PROTECTION: +5V → 5.5V ~ 7.0V, + 3.3V → 4.0V ~ 4.5V . SHORT CIRCUIT:5V,12V,3.3V * EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A * SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950 * REMOTE ON / OFF CONTROL THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY), AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABED * COOLING : TWO 40 mm DC FANS (MODULE) * AC INLET IN EACH MODULE