961-085-000  961-086-000 MARSH BELLORFAM
961-085-000 961-086-000 MARSH BELLORFAM
产品价格:¥1(人民币)
  • 规格:
  • 发货地:上海
  • 品牌:
  • 最小起订量:1个
  • 免费会员
    会员级别:试用会员
    认证类型:未认证
    企业证件:未通过
    认证信息:未认证

    商铺名称:上海冠佑电气自动化有限公司

    联系人:陈尉(先生)

    联系手机:

    固定电话:

    企业邮箱:2265736@163.com

    联系地址:上海市闵行区东川路2759弄

    邮编:200240

    联系我时,请说是在线缆网上看到的,谢谢!

    商品详情
       
      上海冠佑电气自动化有限公司随时欢迎您的来电咨询,低价现货供应 。
      电话:021-60483978  13916770581
      传真:021-34689102  联系人:陈尉
      商务QQ:1305857511  邮箱:2265736@163.com
      网址:www.gyautomation.com
      MARSH BELLORFAM(马士贝罗浮) 电气转换器 一级代理
      Type 1000
       
      Type 1000 I/P & E/P Transducers
      • Low Cost
      • Built-in Volume Booster
      • Small Size
      • Field Reversible
      • Low Air consumption
      • Mounts at Any Angle
      • Convenient External Span & Zero Adjusts
        (Except for Explosion Proof Models)
      • Light Weight
      • Wide Supply Pressure Range
      • Low Supply Pressure Sensitivity
      Product Detail:
      The Type 1000 Transducer is an electro-pneumatic device that reduces a supply pressure to a regulated output pressure directly proportional to an electrical input signal. The Type 1000 accepts a wide range of supply pressures, ranging from a minimum of 3 psig (0.2 BAR) above the maximum output up to 100 psig (6.9 BAR). An integral pneumatic volume booster is included in the design to provide high flow capacity (up to 12 SCFM/339 slpm). Model selections include general purpose, NEMA 4X Type, extended range, high relief, intrinsically safe, and explosion proof.
      Part Numbers:
      T-1000 General Purpose ordering information:
      Input
      Output*
      Part Number
      Impedance
      (nominal)
      psig
      BAR
      4-20mA
      3-9
      0.2-0.6
      961-072-000
      90Ω
      9-15
      0.6-1.0
      961-073-000
      90Ω
      3-15
      0.2-1.0
      961-070-000
      180Ω
      3-27
      0.2-1.9
      961-074-000
      220Ω
      6-30
      0.4-2.1
      961-075-000
      220Ω
      1-17
      0.07-1.2
      961-116-000
      250Ω
      3-15
      0.2-1.0
      961-089-000
      180Ω
      10-50mA
      3-15
      0.2-1.0
      961-076-000
      70Ω
      3-27
      0.2-1.9
      961-077-000
      85Ω
      6-30
      0.4-2.1
      961-078-000
      85Ω
       
      ============
       
      0-5V
      3-15
      0.2-1.0
      961-079-000
      615Ω
      3-27
      0.2-1.9
      961-080-000
      530Ω
      6-30
      0.4-2.1
      961-081-000
      530Ω
      1-9V
      3-15
      0.2-1.0
      961-085-000
      985Ω
      3-27
      0.2-1.9
      961-086-000
      840Ω
      6-30
      0.4-2.1
      961-087-000
      840Ω
      NOTE: For NEMA4X, add 004 suffix.
      T-1000 extended range ordering information:
      Input
      Output*
      Part Number
      Impedance
      (nominal)
      psig
      BAR
      0-60mA
      2-120
      0.1-8.3
      961-107-000
      220Ω
      4-20mA
      3-120
      0.2-8.3
      961-111-000
      260Ω
      2-60
      0.1-4.1
      961-117-000
      225Ω
      0-10V
      3-120
      0.2-8.3
      961-112-000
      805Ω
      0-5V
      2-60
      0.1-4.1
      961-118-000
      500Ω
      T-1000 HIGH RELIEF ordering information:
      Input
      Output*
      Part Number
      Impedance
      (nominal)
      psig
      BAR
      4-20mA
      3-9
      0.2-0.6
      961-130-000
      90Ω
      9-15
      0.6-1.0
      961-131-000
      90Ω
      3-15
      0.2-1.0
      961-132-000
      180Ω
      3-27
      0.2-1.9
      961-133-000
      220Ω
      6-30
      0.4-2.1
      961-134-000
      220Ω
      3-15
      0.2-1.0
      961-135-000
      180Ω
      1-17
      0.07-1.2
      961-136-000
      250Ω
      10-50mA
      3-15
      0.2-1.0
      961-137-000
      70Ω
      3-27
      0.2-1.9
      961-138-000
      85Ω
      6-30
      0.4-2.1
      961-139-000
      85Ω
      * For output pressures less than 3 psi (0.2 BAR) or greater than 30 psi (21 BAR), the Type 1000 transducer can be coupled to Bellofram Type 75 pneumatic relay. Consult Applications Engineers for further information.
      ** NEMA 4 type enclosure option available on all input/output ranges. This option is separate from explosion proof, NEMA 4 units.
       
      Type 1000 Explosion Proof
      Input
      Output*
      Part Number
      Impedance (nominal)
      Agency Approvals
      (see notes)
      psig
      BAR
      4-20mA
      3-15
      0.2-1.0
      961-098-000
      180Ω
      Explosion-Proof, Factory Mutual1
      3-15
      0.2-1.0
      961-098-100
      180Ω
      CSA Explosion Proof
      1-9v
      3-15
      20-100
      961-142-000
      985Ω
      Explosion Proof Factory Mutual1
      Type 1000 Intrinsically Safe
      4-20mA
      3-15
      0.2-1.0
      961-099-000
      180Ω
      Intrinsically Safe, Factory Mutual3,4
      3-27
      0.2-1.9
      961-100-000
      220Ω
      Intrinsically Safe, Factory Mutual3,4
      3-15
      0.2-1.0
      961-105-000
      180Ω
      Intrinsically Safe, CSA5
      3-27
      0.2-1.9
      961-106-000
      220Ω
      Intrinsically Safe, CSA5
      6-30
      0.4-2.1
      961-101-000
      220Ω
      Intrinsically Safe, Factory Mutual3,4
      15-3
      1.0-0.2
      961-175-000
      180Ω
      Intrinsically Safe, Factory Mutual3,4
      27-3
      1.9-0.2
      961-176-000
      220Ω
      Intrinsically Safe, Factory Mutual3,4
      30-6
      2.1-0.4
      961-177-000
      220Ω
      Intrinsically Safe, Factory Mutual3,4
      *For output pressures less than 3 psi or greater than 30 psi the Type 1000 transducer can be coupled to Bellofram Type 75 pneumatic relay.  Consult application engineers for further information.
      Agency Approval Notes:
      1. The Type 1000 Explosion-Proof Transducer has been submitted, tested and approved by Factory Mutual Research for use in hazardous locations for Class I, Division 1, Group D, Class II, Division 1, Groups E, F & G and Class III requirements. It also has been approved to meet NEMA 4 Outdoor requirements.
      2. Canadian Standards Association certified for hazardous locations: Class I, Group D, Class II, Groups E, F and G, Class III, CSA Enc. 4.
      3. Factory Mutual Research Approved as intrinsically Safe for Class I, II, III, Division 1, Groups A, B, C, D, E, G when installed in accordance with interconnection diagram No. 541-000-012 and with the proper energy limiting barriers.
      4. Factory Mutual Research Approved as nonincendive for Class I, Division 2, Groups A, B, C, D, and suitable for Class II and III, Division 2, Group G. Barriers are not required for nonincendive rating.
      5. Canadian Standards Association certified as intrinsically safe when connected through certified diode safety barriers in accordance with Bellofram Installation Instruction 541-000-012.
      Explosion proof, intrinsically safe, and non-incendive ratings are not affected by recalibrating for split range or reverse acting applications.
      The Bellofram T-1000 Transducers were tested and found to comply with Electromagnetic compatibility Directive effective January 1, 1996. The relevant EMC specifications tested were the following: EN 50081-1 (1992) and EN 50082-1 (1992). A Technical Construction File, Serial #107 was written and Certificate of Conformity issued by a Competent Body.
      Options:
      Option
      Part Number/Last 3 digits
      Explosion Proof Mounting Kit
      971-079-000
      Explosion Proof Panel Mounting Kit
      971-078-000
      DIN Rail Kit
      010-115-000
      Hirschman Connector Kit (3-prong)
      971-126-000
      Filter Kit, Coalescing, 0.1 micron
      010-140-000
      Filter Element Kit
      (for coalescing filter, package of 10)
      010-141-000
      Output Gauges–Option “8”
      last 3 digits become - 008
      Dielectric Strength Testing Option “12”
      last 3 digits become - 012
      NEMA 4X Type Enclosure Option: Option “4”
      last 3 digits become - 004**
      ** NEMA 4 type enclosure option available on all input/output ranges. This option is separate from explosion proof, NEMA 4 units.
       
    在线询盘/留言
  • 0571-87774297